DocumentCode :
1045889
Title :
A Closing Switch Shunted by a Triggered Vacuum Gap for Precis Current Initiation
Author :
Porter, J.W. ; Lee, T.H.
Author_Institution :
General Electric Company
Issue :
3
fYear :
1972
fDate :
5/1/1972 12:00:00 AM
Firstpage :
763
Lastpage :
767
Abstract :
This paper describes a device which will provide precise control in the initiation of very high currents required for testing circuit breakers and other power system components. A triggered vacuum gap is used for initiation of current and is then quickly shunted by an electromechanical device for continuous conduction. Application of this device and test results are discussed in detail.
Keywords :
Circuit breakers; Circuit testing; Contacts; Control systems; Electromechanical devices; Inductors; Power system control; Switches; Switching circuits; System testing;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1972.293404
Filename :
4074779
Link To Document :