Title :
Digital magnetic temperature transducer
Author :
Tchernev, Dimiter I. ; Collier, Theodore E.
Author_Institution :
University of Texas, Austin, Tex.
fDate :
9/1/1971 12:00:00 AM
Abstract :
A new digital magnetic temperature transducer is reported. The device utilizes the discontinuous behavior of the initial permeability with temperature at the Curie temperature of some magnetic materials. Since the Curie temperature is determined by the chemical and crystallographic composition of the particular material only, the transducer requires no calibration and has extremely high stability and reproducibility with time. The output of the transducer is inherently digital and, therefore, is directly compatible with the digital information processing and control without A/D conversion. The temperature-sensing portion of the transducer consists only of magnetic cores and wire and, therefore, has extremely high reliability, is shock and radiation insensitive, small, and virtually indestructible.
Keywords :
Curie temperature; Magnetic sensors; Temperature sensors; Calibration; Chemical transducers; Composite materials; Crystalline materials; Crystallography; Magnetic materials; Permeability; Reproducibility of results; Stability; Temperature;
Journal_Title :
Magnetics, IEEE Transactions on
DOI :
10.1109/TMAG.1971.1067075