• DocumentCode
    104746
  • Title

    Influence of the Variation of the Input Parameters on the Simulation Results of a Large Hydrogenerator

  • Author

    Aguiar, Ana B. M. ; Merkhouf, Arezki ; Hudon, C. ; Al-Haddad, Kamal

  • Author_Institution
    Ecole de Technol. Super., Montreal, QC, Canada
  • Volume
    50
  • Issue
    1
  • fYear
    2014
  • fDate
    Jan.-Feb. 2014
  • Firstpage
    261
  • Lastpage
    268
  • Abstract
    Electromagnetic modeling and simulation of hydroelectric generators require a large number of variables for accurate study and test result validation. Simulation results can be affected by mesh density, magnetic material properties, excitation current, and air gap. A finite-element analysis was performed to calculate the relative effect of these variables on a 122.6-MVA, 13.8-kV, 60-Hz, 60-pole, 504-stator slot design. The obtained results were compared with measured parameters such as air-gap flux density, line current, and magnetic core losses.
  • Keywords
    finite element analysis; hydroelectric generators; machine theory; air gap; apparent power 122.6 MVA; electromagnetic modeling; electromagnetic simulation; excitation current; finite element analysis; frequency 60 Hz; hydroelectric generator; input parameter variation; large hydrogenerator; magnetic material properties; mesh density; stator slot design; voltage 13.8 kV; Atmospheric modeling; Generators; Loss measurement; Magnetic cores; Magnetic losses; Magnetic materials; Stators; Air gap; electromagnetic analysis; finite-element method; load modeling; magnetic core;
  • fLanguage
    English
  • Journal_Title
    Industry Applications, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-9994
  • Type

    jour

  • DOI
    10.1109/TIA.2013.2268454
  • Filename
    6531670