DocumentCode :
1052325
Title :
Uncooled IR imaging array based on quartz microresonators
Author :
Vig, John R. ; Filler, Raymond L. ; Kim, Yoonkee
Author_Institution :
US Army Res. Lab., Fort Monmouth, NJ, USA
Volume :
5
Issue :
2
fYear :
1996
fDate :
6/1/1996 12:00:00 AM
Firstpage :
131
Lastpage :
137
Abstract :
A quartz crystal resonator´s resonance frequency is sensitive to temperature. This sensitivity has been exploited in the past in thermometers made of single, macroscopic quartz resonators that can accurately detect temperature changes of μK. Using semiconductor microfabrication techniques, it is now possible to fabricate a large number of microresonators from a single quartz wafer. It is shown that combining the small thermal mass and high thermal isolation capability of such microresonators, the steep frequency versus temperature characteristics of resonators made of certain cuts of quartz and the low-noise characteristics of quartz crystal oscillators can result in high-performance infrared (IR) sensors and sensor arrays. In a microresonator sensor, the temperature change produced by the absorption of IR energy results in a frequency change that can be measured with a resolution that corresponds to a change in the resonator´s temperature of less than a μK. Calculation shows that an array of microresonators in the 200 MHz-1 GHz range can be the basis of an uncooled IR imaging system with a noise equivalent temperature difference, NETD, of <0.01 K. The design and fabrication problems to be overcome before such microresonator arrays can be realized are discussed
Keywords :
crystal resonators; frequency measurement; infrared imaging; micromechanical resonators; semiconductor device noise; 200 MHz to 1 GHz; SiO2; design; fabrication; frequency versus temperature characteristics; high-performance infrared (IR) sensors; low-noise characteristics; microresonator arrays; microresonator sensor; microresonators; noise equivalent temperature difference; oscillator noise; quartz crystal oscillators; quartz microresonators; resonance frequency; semiconductor microfabrication; sensitivity; sensor arrays; thermal isolation capability; thermometers; uncooled IR imaging; uncooled IR imaging array; Infrared sensors; Microcavities; Optical imaging; Oscillators; Resonance; Resonant frequency; Sensor arrays; Sensor phenomena and characterization; Temperature sensors; Thermal sensors;
fLanguage :
English
Journal_Title :
Microelectromechanical Systems, Journal of
Publisher :
ieee
ISSN :
1057-7157
Type :
jour
DOI :
10.1109/84.506201
Filename :
506201
Link To Document :
بازگشت