• DocumentCode
    1055136
  • Title

    Comparison of calibration systems for magnetic field measurement equipment

  • Author

    Frix, William M. ; Karady, George G. ; Venetz, Brian A.

  • Author_Institution
    Arizona State Univ., Tempe, AZ, USA
  • Volume
    9
  • Issue
    1
  • fYear
    1994
  • fDate
    1/1/1994 12:00:00 AM
  • Firstpage
    100
  • Lastpage
    108
  • Abstract
    The current ANSI/IEEE standard specifies two possible methods for magnetic meter calibration: a single square loop or a round Helmholtz coil. However it: (a) does not specify the size of the coil; and (b) does not provide a comparison of the field uniformities between the two suggested systems. In this paper, the z-directed magnetic field equations for four calibration system designs, the single round loop, the round Helmholtz coil, the single square loop, and the square Helmholtz coil are derived and presented
  • Keywords
    calibration; magnetic field measurement; magnetometers; measurement standards; measurement systems; measurement theory; ANSI/IEEE standard; calibration systems; field uniformities; magnetic field measurement; magnetic meter; measurement equipment; round Helmholtz coil; single round loop; single square loop; square Helmholtz coil; z-directed magnetic field equations; ANSI standards; Calibration; Coils; Equations; IEEE members; Magnetic field measurement; Magnetic fields; Measurement standards; Rivers; Shape;
  • fLanguage
    English
  • Journal_Title
    Power Delivery, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8977
  • Type

    jour

  • DOI
    10.1109/61.277684
  • Filename
    277684