DocumentCode :
1058946
Title :
CCE intercomparison of AC-DC transfer standards
Author :
De Vreede, Jan P M
Author_Institution :
Van Swinden Lab., Delft, Netherlands
Volume :
42
Issue :
2
fYear :
1993
fDate :
4/1/1993 12:00:00 AM
Firstpage :
99
Lastpage :
108
Abstract :
A worldwide comparison is described covering both AC voltage and AC current measurements in the frequency range from 40 Hz to 1 MHz. Results are consistent within 10-20 p.p.m. at low voltage and frequency, but differ by up to 100 ppm at high voltage and frequency. For currents of tens of milliamperes the results are consistent within 40 ppm
Keywords :
electric current measurement; measurement standards; voltage measurement; 40 Hz to 1 MHz; AC current measurements; AC voltage; AC-DC transfer standards; CCE intercomparison; voltage measurement; Current measurement; Electronic equipment; Frequency measurement; Helium; Laboratories; Large-scale systems; Low voltage; Modems; NIST; Resistors;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/19.278530
Filename :
278530
Link To Document :
بازگشت