DocumentCode
1068486
Title
Application of Infra-Red Thermography to the Study of Temperature Distribution on Energized Polluted Insulators
Author
El-Arabaty, A. ; Nosseir, A. ; El-Debeiky, S. ; Nasser, E. ; El-Sharkawi, E. ; El-sarky, A.
Author_Institution
Electrical Engineering Department Ain-Shams University Cairo, Egypt
Issue
5
fYear
1979
Firstpage
278
Lastpage
280
Abstract
Temperature distribution on the surface of an energized polluted insulator has been measured using infra-red hermo thermovision techniques. Temporal variation of temperature has also been determined. Tests were carried out on a conventional ional cap and pin insulator unit. Results show that the maximum temperature of the energized insulator could be as high as 100°C at the regions around the pin.
Keywords
Energy measurement; Flashover; Insulation; Pollution measurement; Surface contamination; Surface resistance; Temperature distribution; Thermal pollution; Time measurement; Voltage;