Title :
Calibration of Partial Discharge Detectors for Pulse-Height Distribution Analysis
Author :
Ahmed, Abobakr S. ; Zaky, Asser A.
Author_Institution :
El-Nasr Company for TV & Elect. Cairo, Egypt
Abstract :
The effect of the calibration-pulse fall times, ranging from 0.52-56 ¿s, on the response of partial-discharge detectors using a multichannel analyser has been investigated. Although the equalization of fall/rise time ratio results in a single peak distribution, the latter is sensitive to small variations in this ratio. It is shown that a single peak, single-spectrum, can be obtained for ratios of the order of 50.
Keywords :
Calibration; Circuits; Detectors; Displays; Impedance measurement; Partial discharges; Pulse measurements; Pulse shaping methods; Pulse transformers; Virtual colonoscopy;
Journal_Title :
Electrical Insulation, IEEE Transactions on
DOI :