Abstract
A computational method providing online, automated 3-D reconstruction of the right atrium of the human heart is presented in this paper. Endocardial boundaries were extracted from transesophageal ultrasound data by a topographic cellular contour extraction (TCCE) algorithm. The TCCE method was implemented on a continuous-time, analog, massively parallel processor, and on a digital serial processor. Processing speeds were 500 or 40 frames per second, depending on the hardware used. Extracted boundary point sets were rendered into a 3-D mesh and the volume of the cavity was quantified. Accuracy of volume quantification was validated on 60 in vitro static phantoms and 12 clinical subjects. For the clinical recordings, reference volumes were estimated from manually delineated endocardial boundaries. The average error of volume quantification by the TCCE method was 8% ??5% (n = 12), the average of the interobserver variability between two independent human experts was 5% ??2% (n = 6). Interactive planning of atrial septal defect closure in pediatric cardiology is presented as an example that demonstrates a potential clinical application of the method.
Keywords
echocardiography; edge detection; feature extraction; image reconstruction; medical image processing; paediatrics; parallel processing; volume measurement; 3D mesh; TCCE algorithm; atrial septal defect closure; automated 3D reconstruction; cavity volume quantification; clinical subjects; continuous time analog massively parallel processor; digital serial processor; echocardiography data; endocardial boundary extraction; human heart; in vitro static phantoms; online 3D reconstruction; pediatric cardiology; right atrium; topographic cellular contour extraction algorithm; transesophageal ultrasound data; Cardiology; Data mining; Echocardiography; Hardware; Heart; Humans; Imaging phantoms; In vitro; Three dimensional displays; Ultrasonic imaging; Cellular nonlinear network (CNN); echocardiography; multi-core; online 3-D; parallel; topographic; Algorithms; Child; Echocardiography, Transesophageal; Heart Atria; Humans; Image Processing, Computer-Assisted; Observer Variation; Phantoms, Imaging; Reproducibility of Results;
fLanguage
English
Journal_Title
Biomedical Engineering, IEEE Transactions on
Publisher
ieee
ISSN
0018-9294
Type
jour
DOI
10.1109/TBME.2009.2024315
Filename
5075584
Link To Document