• DocumentCode
    1079771
  • Title

    Positron Emission Tomography-Guided Biopsy With a Dedicated Breast Scanner: Initial Evaluation

  • Author

    Raylman, Raymond R.

  • Author_Institution
    Dept. of Radiol., West Virginia Univ., Morgantown, WV
  • Volume
    56
  • Issue
    3
  • fYear
    2009
  • fDate
    6/1/2009 12:00:00 AM
  • Firstpage
    620
  • Lastpage
    624
  • Abstract
    Efforts to create dedicated nuclear medicine breast imaging scanners are maturing as they approach more routine clinical use. These systems promise to improve the detection of small lesions, especially those in breasts that are not definitively imaged with standard methods. Since these techniques lack sufficient specificity for accurate diagnoses of cancer, a method for guiding biopsies with these new devices must be developed. In this investigation, a technique that capitalizes upon the three-dimensional, multi-angle positron emission tomography (PET) breast images created by our new positron emission mammography/tomography imaging and biopsy device (PEM-PET) to guide breast biopsies was tested. Specifically, the accuracy and precision of the needle positioning system was measured for each of the three axes of motion. In addition, a biopsy of a simulated breast lesion was performed under realistic imaging conditions. The results from the positioning tests revealed that the system had very good accuracy and precision in all three axes. The maximum positioning error was plusmn 0.27 mm, sufficient to obtain samples from most lesions detected with PEM-PET. In addition, the simulated biopsy was performed successfully on a single attempt in obtaining a sample from a 5-mm-diameter target sphere. This successful test moves the project closer to the next phase of development, initiation of limited human testing.
  • Keywords
    biological organs; cancer; mammography; medical image processing; positron emission tomography; PEM; PET; biopsy; clinical use; guided biopsy; human testing; nuclear medicine breast imaging scanners; positron emission mammography; positron emission tomography; Breast biopsy; Cancer; Lesions; Mammography; Motion measurement; Needles; Nuclear medicine; Positron emission tomography; Radioactive decay; Testing; Breast imaging; biopsy; instrumentation; nuclear medicine;
  • fLanguage
    English
  • Journal_Title
    Nuclear Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9499
  • Type

    jour

  • DOI
    10.1109/TNS.2009.2015449
  • Filename
    5076076