DocumentCode :
1083589
Title :
Calibration and normalization of time domain network analyzer measurements
Author :
Dhaene, Tom ; Martens, Luc ; De Zutter, Daniel
Author_Institution :
Lab. of Electromagn. & Acoust., Ghent Univ., Belgium
Volume :
42
Issue :
4
fYear :
1994
fDate :
4/1/1994 12:00:00 AM
Firstpage :
580
Lastpage :
589
Abstract :
In this paper, we present a new advanced calibration and normalization procedure for time domain reflection and transmission (TDR/T-) measurements. Our approach reduces the systematic error of the time domain network analyzer significantly. The error correction is based on a twoport error model, as already known for network analyzers. All measurements proceed in the time domain, while the error correction itself proceeds completely in the frequency domain. This new algorithm calculates the normalized (time domain) TDR/T-pictures as well as the calibrated (frequency domain) S-parameters
Keywords :
S-parameters; calibration; measurement errors; microwave reflectometry; network analysers; time-domain reflectometry; S-parameters; TDR/T-pictures; calibration; error correction; normalization; systematic error; time domain network analyzer measurements; time domain reflection/transmission measurements; twoport error model; Cables; Calibration; Error correction; Frequency domain analysis; Frequency measurement; Modems; Oscilloscopes; Time domain analysis; Time measurement; Voltage;
fLanguage :
English
Journal_Title :
Microwave Theory and Techniques, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9480
Type :
jour
DOI :
10.1109/22.285063
Filename :
285063
Link To Document :
بازگشت