    An ultrasound synthetic aperture imaging method based on a monostatic approach was studied experimentally. The proposed synthetic aperture method offers good dynamical resolution along with fast numerical reconstruction. In this study complex object data were recorded coherently in a two-dimensional hologram using a 3.5 MHz single transducer with a fairly wide-angle beam. Image reconstruction which applies the wavefront backward propagation method and the near-field curvature compensation was performed numerically in a microcomputer using the spatial frequency domain. This approach allows an efficient use of the FFT-algorithms. Because of the simple and fast scanning scheme and the efficient reconstruction algorithms the method can be made real-time. The image quality of the proposed method was studied by evaluating the spatial and dynamical resolution in a waterbath and in a typical tissue-mimicking phantom. The lateral as well as the range resolution (-6 dB) were approximately 1 mm in the depth range of 30-100 mm. The dynamical resolution could be improved considerably when the beam width was made narrower. Although it resulted in a slightly reduced spatial resolution this compromise has to be done for better resolution of low-contrast targets such as cysts. The study showed that cysts as small as 2 mm by diameter could be resolved.<>
  • Keywords
    acoustic imaging; biomedical ultrasonics; compensation; fast Fourier transforms; image reconstruction; medical image processing; 2 mm; 3.5 MHz; 30 to 100 mm; FFT-algorithm; US imaging; beam width; cyst imaging; dynamical resolution; fast numerical reconstruction; fast scanning scheme; image quality; medical imaging; microcomputer calculation; monostatic method; near-field curvature compensation; real-time method; spatial frequency domain; tissue-mimicking phantom; two-dimensional hologram; ultrasound synthetic aperture imaging; wavefront backward propagation method; Frequency domain analysis; Image quality; Image reconstruction; Image resolution; Imaging phantoms; Microcomputers; Reconstruction algorithms; Spatial resolution; Ultrasonic imaging; Ultrasonic transducers;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/58.285467
  • Filename
    285467