Optimum load matching in direct-coupled photovoltaic power systems-application to resistive loads
Author :
Khouzam, Kamel Y.
Author_Institution :
Dept. of Electr. Eng., Cleveland State Univ., OH, USA
Volume :
5
Issue :
2
fYear :
1990
fDate :
6/1/1990 12:00:00 AM
Firstpage :
265
Lastpage :
271
Abstract :
The load matching factor is used as a measure for the quality of load matching to a photovoltaic (PV) array. An optimization approach is used to solve the load matching problem with the objective of maximizing the load matching factor, and consequently the PV output energy. This approach is then applied to resistive loads (with and without an internal EMF) connected to the array. Results show that optimum matching can be achieved by carefully selecting the array parameters with respect to the load parameters. The temperature of the array has little effect on the optimum matching factor. However, the optimum matching parameters are greatly affected by the array temperature. A maximum power tracker may not be achieved
Keywords :
load (electric); photovoltaic power systems; array temperature; direct-coupled photovoltaic power systems; load matching; optimization; resistive loads; Battery charge measurement; Character generation; Optical arrays; Photovoltaic systems; Power generation; Solar power generation; Sun; Temperature; Thermal factors; Thermal resistance;
fLanguage :
English
Journal_Title :
Energy Conversion, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-8969
Type :
jour
DOI :
10.1109/60.107220
Filename :
107220
Link To Document :