• DocumentCode
    1102680
  • Title

    Test Fixtures for RF Susceptibility Testing

  • Author

    Bock, Ernst L.

  • Author_Institution
    Consulting Radio Physicist in Sepulveda, Calif
  • Issue
    4
  • fYear
    1973
  • Firstpage
    201
  • Lastpage
    201
  • Abstract
    The most likely standard test fixture for RF susceptibility testing is the twin-strip transmission line, or its half-space counterpart. Its capacitance per meter (length) is 2¿ or 4¿; characteristic impedance Zc= Z0/2 or Z0/4; voltage gradient Ez = V/w or 2 V/w; magnetic field Hy = V/w Z0 or 2 V/w Z0, respectively.
  • Keywords
    Conductors; Dipole antennas; Fixtures; Load flow; Power transmission lines; Radio frequency; Strips; Surface impedance; Testing; Voltage;
  • fLanguage
    English
  • Journal_Title
    Electromagnetic Compatibility, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9375
  • Type

    jour

  • DOI
    10.1109/TEMC.1973.303299
  • Filename
    4090783