• DocumentCode
    1102996
  • Title

    Modified method of high alternating current measurement

  • Author

    Bera, S.C. ; Kole, D.N. ; Mandal, M.

  • Author_Institution
    Dept. of Appl. Phys., Univ. of Calcutta, Kolkata
  • Volume
    2
  • Issue
    3
  • fYear
    2008
  • fDate
    5/1/2008 12:00:00 AM
  • Firstpage
    107
  • Lastpage
    113
  • Abstract
    The conventional current transformers (CTs) in the form of a bar primary and secondary winding on a highly permeable ring core suffer from ratio error and phase angle errors, which are primarily due to the no-load current of the transformer. A modified design of a CT has been described. In this design, a feedback technique has been used in order to reduce the no-load current to a negligibly small value so that the said error may be minimal. Using this technique, a CT has been designed and fabricated with the commercially available material. The performance of the transformer has been tested experimentally and the output and input AC waves have been observed in a storage cathode ray oscilloscope (CRO) and the experimental results are reported.
  • Keywords
    current transformers; electric current measurement; transformer windings; CRO; CT; alternating current measurement; cathode ray oscilloscope; conventional current transformers; feedback technique; no-load current; permeable ring core; phase angle errors; ratio error; transformer windings;
  • fLanguage
    English
  • Journal_Title
    Science, Measurement & Technology, IET
  • Publisher
    iet
  • ISSN
    1751-8822
  • Type

    jour

  • DOI
    10.1049/iet-smt:20070029
  • Filename
    4472210