• DocumentCode
    1104178
  • Title

    The Effect of Mutual Inductance and Mutual Capacitance on the Transient Response of Braided-Shield Coaxial Cables

  • Author

    Merewether, David E. ; Ezell, T. Frank

  • Author_Institution
    Mission Research Corporation, Albuquerque, NM 87108
  • Issue
    1
  • fYear
    1976
  • Firstpage
    15
  • Lastpage
    20
  • Abstract
    A quantitative comparison is made of the importance of mutual inductance and mutual capacitance in the leakage of transient signals through the braid of a coaxial cable. The difference between mutual inductance and mutual capacitance coupling is vividly exhibited in the transient predictions. Comparisons of predictions to measurements made on a length of RG-214 test cable are also included.
  • Keywords
    Cable shielding; Capacitance; Circuits; Coaxial cables; Electrical resistance measurement; Impedance measurement; Inductance; Length measurement; Mutual coupling; Transient response;
  • fLanguage
    English
  • Journal_Title
    Electromagnetic Compatibility, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9375
  • Type

    jour

  • DOI
    10.1109/TEMC.1976.303450
  • Filename
    4090940