DocumentCode
1104469
Title
On the Effective Transfer Impedance of Thin Coaxial Cable Shields
Author
Casey, Kendall F.
Author_Institution
Department of Electrical Engineering, Kansas State University, Manhattan, KS 66506
Issue
3
fYear
1976
Firstpage
110
Lastpage
117
Abstract
It is shown that the effective transfer impedance per unit length of a thin coaxial cable shield is given by Zs h2/Ys, where ZS and Ys are, respectively, the cable´s inductive transfer impedance per unit length and capacitive transfer admittance per unit length, and h is the axial propagation constant. This general result is illustrated by consideration of a specific shield model, the M-filar filamentary helix.
Keywords
Admittance; Cable shielding; Coaxial cables; Communication cables; Conductors; Equations; Impedance; Propagation constant; Transmission lines; Voltage;
fLanguage
English
Journal_Title
Electromagnetic Compatibility, IEEE Transactions on
Publisher
ieee
ISSN
0018-9375
Type
jour
DOI
10.1109/TEMC.1976.303480
Filename
4090973
Link To Document