• DocumentCode
    1105153
  • Title

    Results of magnetic field measurements of SPring-8 magnets

  • Author

    Ohnishi, J. ; Kawakami, M. ; Fujii, K. ; Matsui, S. ; Kumagai, N.

  • Author_Institution
    SPring-8, Kamigori-cho, Ako-gun, Hyogo, Japan
  • Volume
    32
  • Issue
    4
  • fYear
    1996
  • fDate
    7/1/1996 12:00:00 AM
  • Firstpage
    3069
  • Lastpage
    3072
  • Abstract
    Magnetic measurements have been performed for all dipoles, quadrupoles and sextupoles of the SPring-8 storage ring. The long flip coil and the rotating coil system were used for the measurements and they were good enough in measurement accuracy. Dispersion of the magnetic length and strength of the multipole fields were found to be within tolerable range for the three types of magnet. The position of the fiducial points for alignment was measured in the accuracy of better than 20 μm for all the quadrupoles and the sextupoles
  • Keywords
    accelerator magnets; coils; electromagnets; electron accelerators; magnetic field measurement; storage rings; synchrotron radiation; SPring-8 magnets; dipole magnets; fiducial points; flip coil; magnetic field measurements; magnetic length; measurement accuracy; multipole fields; quadrupole magnets; rotating coil system; sextupole magnets; storage rings; synchrotron radiation source; Boring; Coils; Current measurement; Extraterrestrial measurements; Magnetic field measurement; Magnets; Performance evaluation; Rotation measurement; Storage rings; Synchrotron radiation;