DocumentCode :
1106238
Title :
Reference Potential Terms in Static Capacitance Calculations Via the Method of Moments
Author :
Paul, Clayton R.
Author_Institution :
Department of Electrical Engineering, University of Kentucky, Lexington, KY 40506. (606) 258-8616
Issue :
1
fYear :
1978
Firstpage :
267
Lastpage :
269
Abstract :
In an earlier publication [1], a numerical method for determining the per-unit-length generalized capacitance matrix for a system of parallel cylindrical conductors with cylindrical dielectric insulations (wires) was given. In the formulation of the method, potential expressions were developed in which reference-potential terms were omitted. In this paper, a proof of the validity of omitting the reference-potential terms is presented.
Keywords :
Bismuth; Cable insulation; Capacitance; Conductors; Dielectrics and electrical insulation; Moment methods; Transmission line matrix methods; Transmission lines; Voltage; Wires; Capacitance matrix; proof; reference-potential terms; valid omission;
fLanguage :
English
Journal_Title :
Electromagnetic Compatibility, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9375
Type :
jour
DOI :
10.1109/TEMC.1978.303657
Filename :
4091158
Link To Document :
بازگشت