• DocumentCode
    1108046
  • Title

    Machine stator iron evaluation through the use of resonant circuits

  • Author

    Timperley, J.E. ; Bristor, A.F.

  • Author_Institution
    AEP Service Corporation, Columbus, OH
  • Issue
    3
  • fYear
    1986
  • Firstpage
    94
  • Lastpage
    100
  • Abstract
    The resonant system described here has several advantages: Calculations are simple, wide flux control is provided and power loss is easy to supply and accurately measure. Safety during a test is improved, since the resonance condition will collapse if circuit failure occurs. The system may not be resonaqt if extensive iron shorts exist and, with lower bus current requirements, breakers or fuses can be coordinated for better protection.
  • Keywords
    Capacitors; Circuit testing; Control systems; Impedance matching; Iron; Power supplies; RLC circuits; Resonance; Stators; Voltage;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/TEC.1986.4765740
  • Filename