• DocumentCode
    111052
  • Title

    Integrated Biosensing Platform Based on a 1.74-mW −90-dBm Sensitivity Dual- Mode-Operation Receiver for IEEE 802.15.6 Human Body Communication Standard

  • Author

    Yu Lin Tsou ; Gong, Cihun-Siyong Alex ; Nai Chen Cheng ; Yu Lee ; Jou, Christina F.

  • Author_Institution
    Dept. of Low-Power Mixed-Signal, Ind. Technol. Res. Inst., Hsinchu, Taiwan
  • Volume
    15
  • Issue
    6
  • fYear
    2015
  • fDate
    Jun-15
  • Firstpage
    3317
  • Lastpage
    3327
  • Abstract
    Human body communication (HBC), a technique featuring low conduction loss and low interference by taking the advantages of the nature of body composition, has emerged as one of the most promising techniques toward next-generation wireless body area network (WBAN). The regulation of WBAN, IEEE 802.15.6, concerning the standard of physical layer has also been established in 2012. The intensity of electric field around body is affected by the transmission distance, quality of electrode-skin contact, and so on which results in wide variance in path loss. In addition, according to the measurement results, the equivalent capacitance of electrode-skin interface increases path loss significantly when noncontact transmission happens. To solve the problems, a low-power receiver with dual-mode operation is proposed in this paper. The receiver has been implemented in a standard 0.18-μm CMOS process measurement shows the receiver is fully functional with power consumption <;1.75 mW under 1.2 V supply voltage and compatible with IEEE 802.15.6 HBC layer. The chip size is 1.05 mm2. Maximum voltage conversion gain can be 85.5 dB. Experimental sensitivity is up to -90 dBm under an information data rate of 164 kb/s. It has been demonstrated that the receiver provides successful text file transmission through human body with the fabricated sensing electrodes.
  • Keywords
    CMOS integrated circuits; biomedical electrodes; biomedical electronics; body area networks; body sensor networks; receivers; skin; telemedicine; CMOS process measurement; HBC layer; WBAN regulation; electric field intensity; electrode-skin contact quality; electrode-skin interface; fabricated sensing electrodes; human body communication; integrated biosensing platform; low-power dual-mode-operation receiver; power consumption; text file transmission; transmission distance; wireless body area network; Capacitance; Electrodes; Loss measurement; Mixers; Propagation losses; Receivers; Standards; Dual-mode; FSDT; HBC; Receiver; WBAN; dual-mode; low power; receiver; sensitivity;
  • fLanguage
    English
  • Journal_Title
    Sensors Journal, IEEE
  • Publisher
    ieee
  • ISSN
    1530-437X
  • Type

    jour

  • DOI
    10.1109/JSEN.2014.2386353
  • Filename
    6998930