Title :
115-kV Submarine Cable Crossing of Puget Sound
Author_Institution :
The Okonite Company, a subsidiary of Kennecott Copper Corporation, Passaic, N. J.
Abstract :
115-kV lengths of oil-filled submarine cable were manufactured. Tests on samples from the center of 12 800-foot lengths were equal to tests on short lengths. Oil flow tests conducted in the factory and field tests of oil pressure are compared with calculated data. A flexible splice for emergency use was designed and tested.
Keywords :
Cable shielding; Circuits; Costs; Manufacturing; Oil filled cables; Petroleum; Power cable insulation; Power cables; Production facilities; Underwater cables;