Title :
Zirconium fluoride glass fiber radiometer for low temperature measurements
Author :
Mordon, Serge R. ; Buys, Bruno ; Moschetto, Yves
Author_Institution :
INSERM, Lille, France
fDate :
7/1/1989 12:00:00 AM
Abstract :
Infrared signal transmission through zirconium fluoride glass fibers is used for noncontact temperature measurement. A radiometer was developed for temperature measurement between 30°C and 150°C. The dependence of the radiometer signal on the black-body temperature is presented. Experimental and theoretical results are compared
Keywords :
fibre optic sensors; infrared detectors; radiometers; temperature measurement; thermometers; zirconium compounds; 30 to 150 degC; IR; ZrF4; black-body temperature; glass fiber radiometer; low temperature measurements; noncontact temperature measurement; Detectors; Electromagnetic measurements; Glass; Optical fiber communication; Radiometry; Solids; Temperature measurement; Temperature sensors; Wavelength measurement; Zirconium;
Journal_Title :
Lightwave Technology, Journal of