DocumentCode
1139997
Title
Space Radiation Damage Measurements in the Earth Synchronous Orbit
Author
Sarles, F. Williams, Jr. ; Stanley, Alan G. ; Roberge, James K. ; Godfrey, Beverly W.
Author_Institution
M.I.T. Lincoln Laboratory Lexington, Mass. 02173
Issue
6
fYear
1973
Firstpage
921
Lastpage
924
Abstract
For direct measurement of the integrated radiation dose experienced in Earth synchronous orbit, p-i-n diodes were flown as radiation dosimeters on LES-6. The diode, which has a lifetime of 10-4 seconds in the intrinsic region, was originally developed as a neutron dosimeter, but can detect 1-MeV electron fluences as low as 1013 e·cm-2. Observations over three years in orbit are presented.
Keywords
Earth; Electrons; Energy measurement; Extraterrestrial measurements; Neutrons; P-i-n diodes; Photovoltaic cells; Protons; Satellites; Silicon devices;
fLanguage
English
Journal_Title
Aerospace and Electronic Systems, IEEE Transactions on
Publisher
ieee
ISSN
0018-9251
Type
jour
DOI
10.1109/TAES.1973.309668