DocumentCode :
1162513
Title :
Turbine Overspeed Control Behaviour
Author :
Schatzmann, G.P.
Author_Institution :
BBC Brown Boveri & Company, Limited
Issue :
7
fYear :
1981
fDate :
7/1/1981 12:00:00 AM
Firstpage :
3371
Lastpage :
3378
Abstract :
In recent years various power system failures have resulted in major power failures (black-outs). A modern system of turbine control can do much to avoid the serious results of such failures. Apart from a rapid system of speed or load-frequency control, it requires certain supplementary elements, such as HP and LP bypass and acceleration limiter. With such a control system it is possible to contend with the most difficult of all transients, i.e. load shedding to house load.
Keywords :
Acceleration; Boilers; Control systems; Frequency synchronization; Power generation; Power system transients; Power systems; Safety devices; Turbines; Valves;
fLanguage :
English
Journal_Title :
Power Apparatus and Systems, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9510
Type :
jour
DOI :
10.1109/TPAS.1981.316679
Filename :
4111016
Link To Document :
بازگشت