• DocumentCode
    1163130
  • Title

    Study on AC pollution flashover performance of composite insulators at high altitude sites of 2800-4500 m

  • Author

    Jiang, Xingliang ; Yuan, Jihe ; Zhang, Zhijin ; Hu, Qin ; Cheng, Aijun

  • Author_Institution
    State Key Lab. of Power Transm. Equip. & Syst. Security & New Technol., Chongqing Univ., Chongqing
  • Volume
    16
  • Issue
    1
  • fYear
    2009
  • fDate
    2/1/2009 12:00:00 AM
  • Firstpage
    123
  • Lastpage
    132
  • Abstract
    The newly constructed Qinghai-Tibet Railway connecting Golumd and Lhasa is the highest railway in the world, which is located on the hinterland of Qinghai- Tibet Plateau with the average altitude of above 4000 m. Therefore, the external insulation of electric equipments will be affected by the atmospheric conditions in the high altitude regions. In contrast to many test investigations in the artificial climate chamber, there are few ones at the high altitude sites of 3000 m and above. In the paper, the AC artificial pollution tests of four types of composite insulators are carried out at three high altitude sites of 2820 m, 3575 m and 4484 m along the Qinghai-Tibet Railway. The test results show that the AC pollution flashover voltages in high altitude regions are affected not only by the pollution grades but also by the atmospheric parameters. The pollution flashover voltages will decrease with the increase of air pressure but increase with the decreases of ambient temperature. The exponent characterizing the influence of equivalent salt deposit density is 0.26 to 0.32 and the exponent characterizing the influence of non-soluble deposit density is 0.12 to 0.16, the influence of non-soluble deposit density cannot be neglected. The exponent characterizing the influence of air pressure is 0.507 to 0.587. The exponent characterizing the influence of ambient temperature is about 0.20. Considering the combined influence of the air pressure and ambient temperature, the AC flashover voltage of the polluted composite insulators will decrease by 4.0% to 6.4% for the altitude increased per 1000 m.
  • Keywords
    composite insulators; flashover; insulator contamination; insulator testing; AC artificial pollution test; AC pollution flashover voltage performance; Qinghai-Tibet railway; artificial climate chamber; atmospheric condition; composite insulator; distance 2800 m to 4500 m; electric equipment insulation; nonsoluble deposit density; salt deposit density; Air pollution; Dielectrics and electrical insulation; Flashover; Joining processes; Power supplies; Rail transportation; Rivers; Temperature; Testing; Voltage; High altitude, AC composite insulator, pollution flashover, pollution grade, atmospheric parameter;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/TDEI.2009.4784559
  • Filename
    4784559