DocumentCode
1163864
Title
Calibrated noise figure measurements in vector network analyser
Author
Otegi, N. ; Collantes, J.M. ; Sayed, M.
Author_Institution
Electr.ity & Electron. Dept., Univ. of the Basque Country, Bilbao, Spain
Volume
41
Issue
18
fYear
2005
Firstpage
999
Lastpage
1000
Abstract
Calibrated noise figure measurements performed in a vector network analyser are reported. To obtain these measurements, a receiver noise calibration procedure based on analytical calculation is proposed. The procedure is highly compatible with standard SOLT scattering parameter calibration and is especially adapted for simultaneous S-parameter and noise figure measurements. Measurement results on an experimental setup from 1 to 2 GHz are given.
Keywords
S-parameters; calibration; electric noise measurement; microwave measurement; network analysers; 1 to 2 GHz; S-parameter; calibrated noise figure measurements; receiver noise calibration; standard SOLT scattering parameter calibration; vector network analyser;
fLanguage
English
Journal_Title
Electronics Letters
Publisher
iet
ISSN
0013-5194
Type
jour
DOI
10.1049/el:20051718
Filename
1507059
Link To Document