DocumentCode :
1167833
Title :
The D.c. Decay Test for Determining Synchronous Machine Parameters: Measurement and Simulation
Author :
Turner, P.J. ; Reece, A.B.J. ; MacDonald, D.C.
Author_Institution :
G.E.C. Turbine Generators Ltd., Stafford, England
Volume :
9
Issue :
12
fYear :
1989
Firstpage :
38
Lastpage :
38
Abstract :
The d.c. flux decay test has been proposed as an alternative and attractive method of extracting synchronous machine parameters. With the machine stationary, direct current is passed through two phases and the decay of current is observed following the short-circuiting of the supply. Tests on two large turbinegenerators have been performed and simulated by finite element electromagnetic calculations. The combination of tests, calculations and analysis has enabled the cause of various difficulties associated with the test to be isolated. Recommendations are made to improve the accuracy of measurements.
Keywords :
Circuit simulation; Circuit testing; Contact resistance; Current supplies; Finite element methods; Power system simulation; Power system transients; Stators; Synchronous machines; System testing;
fLanguage :
English
Journal_Title :
Power Engineering Review, IEEE
Publisher :
ieee
ISSN :
0272-1724
Type :
jour
DOI :
10.1109/MPER.1989.4310421
Filename :
4310421
Link To Document :