DocumentCode :
1180643
Title :
Reduction of interference in oscillometric arterial blood pressure measurement using fuzzy logic
Author :
Lin, Chin-Teng ; Liu, Shing-Hong ; Wang, Jia-Jung ; Wen, Zu-Chi
Author_Institution :
Dept. of Electr. & Control Eng., Nat. Chiao Tung Univ., Hsinchu, Taiwan
Volume :
50
Issue :
4
fYear :
2003
fDate :
4/1/2003 12:00:00 AM
Firstpage :
432
Lastpage :
441
Abstract :
In oscillometry, oscillation amplitudes (OAs) embedded in the cuff pressure are drastically affected by a variety of artifacts and cardiovascular diseases, leading to inaccurate arterial blood pressure (ABP) measurement. The purpose of this paper is to improve the accuracy in the arterial pressure measurement by reducing interference in the OAs using a recursive weighted regression algorithm (RWRA). This method includes a fuzzy logic discriminator (FLD) and a recursive regression algorithm. The FLD is used to reduce the effect of artifacts caused by measurement motion disturbance or cardiovascular diseases, and to determine the truthfulness of the oscillation pulse. According to the truth degree, the relationship between the cuff pressure and OA is reconstructed using the regression algorithm. Because the regression method must utilize inverse matrix operation, which will be difficult to implement in an automatic or ambulatory monitor, the recursive regression method is proposed to solve this problem. To test the performance of this RWRA, 47 subjects underwent the ABP measurement using both the auscultation and the oscillometry combined with the RWRA. It was found that the average difference between the pooled blood pressures measured by the auscultation and those by the oscillometry combined with the RWRA was found to be only 4.9 mmHg. Clinical results demonstrated that the proposed RWRA is more robust than the traditional curve fitting algorithm (TCFA). We conclude that the proposed RWRA can be applied to effectively improve the accuracy of the oscillometric blood pressure measurement.
Keywords :
blood pressure measurement; blood vessels; cardiovascular system; diseases; fuzzy logic; medical signal processing; patient monitoring; recursive estimation; signal reconstruction; statistical analysis; accuracy; ambulatory monitor; artifacts; auscultation; automatic blood-pressure monitors; automatic monitor; cardiovascular diseases; cuff pressure; fuzzy logic; fuzzy logic discriminator; interference reduction; inverse matrix operation; measurement motion disturbance; oscillation amplitudes; oscillation pulse truthfulness; oscillometric arterial blood pressure measurement; pooled blood pressures; recursive regression algorithm; recursive weighted regression algorithm; truth degree; Arterial blood pressure; Biomedical monitoring; Blood pressure; Cardiovascular diseases; Computerized monitoring; Fuzzy logic; Interference; Motion measurement; Pressure measurement; Pulse measurements; Adolescent; Adult; Aged; Aged, 80 and over; Algorithms; Artifacts; Blood Pressure; Blood Pressure Determination; Cardiovascular Diseases; Diastole; Female; Fuzzy Logic; Humans; Male; Middle Aged; Models, Cardiovascular; Oscillometry; Periodicity; Quality Control; Regression Analysis; Systole;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2003.809502
Filename :
1193776
Link To Document :
بازگشت