DocumentCode :
1193653
Title :
Truly Transportable Standard-Cell Air Bath
Author :
Braudaway, David W.
Volume :
19
Issue :
4
fYear :
1970
Firstpage :
263
Lastpage :
266
Abstract :
Dissemination of the volt is complicated by the complex temperature response of standard cells. Discribed are the design and performance characteristics of an experimental standard-cell airbath specifically optimized for transportable voltage-dissemination service. Salient features of this bath are 1) ±0.001°C control of the cell temperature in the laboratory, ±0.02°C maximum variation around 28°C in shipment; 2) exposure capacity from over 8 hours at 0°C or 45°C to over 72 hours in moderate temperatures; 3) shipping package weight 14.5 kg, size 20.3 × 22.9 × 30.5 cm; and 4) electrical power drain 0.8-0.2 watt. Cell temperature is determined primarily by an ambient-temperature-biased on-off heater system. Immunity to external environment is achieved by a unique secondary control, which employs the energy storage capacity of two heat-of-fusion alloys, which are reset simply by exposure to laboratory temperature. Experience with this bath has shown that the average value of cell voltage is reproducible to 0.1 ¿v within a few hours following shipment. This time delay is significantly shorter than the days-to-weeks for most air baths and the weeks-to-months for cells shipped without temperature control.
Keywords :
Associate members; Cadmium; Design optimization; Electric shock; Laboratories; Size control; Standards development; Surface resistance; Temperature control; Voltage control;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.1970.4313911
Filename :
4313911
Link To Document :
بازگشت