DocumentCode :
1195060
Title :
Microwave Peak Power Measurement Independent of Detector Characteristics by Comparison of Video Samples
Author :
Weinert, Fritz K. ; Weinsch, Bruno O.
Volume :
21
Issue :
4
fYear :
1972
Firstpage :
474
Lastpage :
479
Abstract :
For measurement of RF pulse power, a 100 percent square-wave-modulated reference RF power is interlaced with the pulses. 100-ns-long samples are taken after detection from both the demodulated pulse and square wave. The level of the reference power is adjusted until both samples are equal. This method is independent of the temperature coefficient, law or stability of the detection efficiency. The method is compared with the notch wattmeter, crystal video-detector chopper, and sampling comparison using crystal switches.
Keywords :
Diodes; Envelope detectors; Gas detectors; Power measurement; Pulse measurements; Radio frequency; Resistors; Sampling methods; Temperature dependence; Voltage;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.1972.4314070
Filename :
4314070
Link To Document :
بازگشت