• DocumentCode
    1203643
  • Title

    Control implementation of a five-leg AC-AC converter to supply a three-phase induction machine

  • Author

    Bouscayrol, A. ; Francois, B. ; Delarue, P. ; Niiranen, J.

  • Author_Institution
    Lab. of Electr. Eng., Univ. de Lille, Villeneuve d´Ascq, France
  • Volume
    20
  • Issue
    1
  • fYear
    2005
  • Firstpage
    107
  • Lastpage
    115
  • Abstract
    A fault-tolerant ac-ac converter capable of supplying a three-phase induction machine from the grid with an unitary power factor has been proposed. With one faulted converter leg, two of the remaining five legs are connected to the grid, two legs are connected to the machine, and a common leg is shared by the grid and the machine. The previously developed control strategy required a too great computation time for practical implementation. In this paper, a new control strategy is suggested for this power converter. It enables an easier control implementation. Experimental results are provided.
  • Keywords
    AC-AC power convertors; asynchronous machines; fault tolerance; machine control; power factor; fault tolerant ac-ac converter; five-leg ac-ac converter; power factor; power grid; three-phase induction machine; Bridge circuits; Capacitors; Electricity supply industry; Fault tolerance; Induction machines; Leg; Pulse width modulation converters; Reactive power; Signal processing algorithms; Voltage; Power converter; three-phase induction machine; unitary power factor;
  • fLanguage
    English
  • Journal_Title
    Power Electronics, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8993
  • Type

    jour

  • DOI
    10.1109/TPEL.2004.839826
  • Filename
    1377398