Title :
Comments on "Threshold 60-Hz Current Required for Ventricular Fibrillation in Subjects of Various Body Weights
Author :
Geselowitz, D.B.
Author_Institution :
Bioengineering Program, Pennsylvania State University, University Park, Pa., 16802.
Abstract :
Lead vector theory of electrocardiography is used to estimate cardiac current density thresholds for ventricular fibrillation from reported data for current thresholds at the skin. The estimated value, which is of the order of 300??A/cm2 is consistent with results obtained by others with 60 Hz currents injected directly into the heart.
Keywords :
Animals; Current density; Electrocardiography; Electrodes; Fibrillation; Heart; Humans; Shape; Skin; Threshold current;
Journal_Title :
Biomedical Engineering, IEEE Transactions on
DOI :
10.1109/TBME.1974.324341