DocumentCode
1210340
Title
The Log Count Rate Period Meter Used with Safety Circuits
Author
Christensen, Helge ; Stanfield, Robert B.
Author_Institution
Royal Norwegian Council for Industrial and Scientific Research
Volume
8
Issue
3
fYear
1961
fDate
7/1/1961 12:00:00 AM
Firstpage
22
Lastpage
26
Abstract
Equations are presented that give the probable rate of spurious reactor scrams due to counter noise in the period circuits commonly used at low reactor power. It is shown how a filter introduced to reduce the spurious scram rate, will delay the circuit response in the case of true emergencies. A numerical example shows that a compromise can be reached that gives a very satisfactory circuit.
Keywords
Circuit noise; Counting circuits; Diodes; Equations; Filters; Inductors; Neutrons; Safety; Smoothing methods; Voltage;