• DocumentCode
    1215977
  • Title

    Gas-Breakdown Transmit-Receive Tube Turn-On Times

  • Author

    Smith, Richard S., III ; Thomas, Gary E. ; Coleman, Don C. ; Pappalardo, Thomas J.

  • Volume
    14
  • Issue
    1
  • fYear
    1986
  • Firstpage
    63
  • Lastpage
    66
  • Abstract
    The first measured sub-nanosecond gas-breakdown microwave receiver protector turn-on times are reported. A technique to measure turn-on times as short as 0.35 ns is described. The turn-on time of an X-band gas-breakdown transmit-receive (TR) tube, both alone and when backed by a solid-state diode limiter (DL), is measured to be a small fraction of a nanosecond. The spike leakage energy and transmitted peak power are measured as functions of incident power up to 2 kW. Extrapolation of the results indicates that effective receiver protection might be achieved at gigawatt incident power levels.
  • Keywords
    Calibration; Detectors; Diodes; Oscilloscopes; Power measurement; Protection; Pulse measurements; Saturation magnetization; Testing; Time measurement;
  • fLanguage
    English
  • Journal_Title
    Plasma Science, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0093-3813
  • Type

    jour

  • DOI
    10.1109/TPS.1986.4316499
  • Filename
    4316499