DocumentCode :
1217553
Title :
Considerations Affecting the Mitigation of Noise Coupled Between Cable Pairs
Author :
Ward, Henry C.
Author_Institution :
New Jersey Bell Telephone Co., Newark, NJ
Volume :
15
Issue :
4
fYear :
1967
fDate :
8/1/1967 12:00:00 AM
Firstpage :
648
Lastpage :
652
Abstract :
Certain mitigative measures which can be employed against metallic noise coupled into telephone circuits in the outside plant are discussed. Quantitative restults are given for separate entrance cable, flat gain amplifiers, arid noise suppression coils. The model used appears to be well-suited to the typical impulse noise problem.
Keywords :
Amplifiers; Audio frequency; Crosstalk; Outside plant; Repeaters; Subscriber loops; Telephone equipment; Telephone systems; Transmission; signal-to-noise ratio (SNR); Circuit noise; Communication cables; Communications technology; Conductors; Crosstalk; Noise level; Noise measurement; Repeaters; Signal to noise ratio; Telephony;
fLanguage :
English
Journal_Title :
Communication Technology, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9332
Type :
jour
DOI :
10.1109/TCOM.1967.1089621
Filename :