A Deconvolution Procedure for Use in Extracting Information in Average Evoked Response EEG Signals
Author :
Sjøntoft, Erik
Author_Institution :
Physics Laboratory II, H. C. Ã\x98rsted Institute, Copenhagen, Denmark and the Institute for Experimental Research in Surgery, University of Copenhagen
Issue :
4
fYear :
1980
fDate :
4/1/1980 12:00:00 AM
Firstpage :
227
Lastpage :
230
Abstract :
An EEG signal improvement which uses a deconvolution technique is presented. One example where this technique has been used is shown. A noticeable improvement in time localization of peaks in an AER recording was demonstrated.