DocumentCode :
1226624
Title :
Determination of motor quality through routine electrical tests
Author :
Soukup, George C.
Author_Institution :
US Electr. Motors, St. Louis, MO, USA
Volume :
25
Issue :
5
fYear :
1989
Firstpage :
873
Lastpage :
880
Abstract :
Tests representing mechanical and electrical testing that can be performed on fully assembled motors are described. Associated benefits along with the corresponding costs are identified. The tests covered are heat run, performance locked-rotor, speed-torque, no-load-saturation, surge, high-potential, polarization-index, single-phase-rotor, Reed-critical-frequency, hot/cold vibration coastdown-critical, and bearing tests. General guidelines for test procedures are provided
Keywords :
electric motors; machine testing; Reed-critical-frequency; bearing tests; electrical tests; heat run; high potential tests; hot/cold vibration coastdown-critical; mechanical testing; motor quality; no-load-saturation; performance locked-rotor; polarization-index; single-phase-rotor; speed-torque tests; Acoustic testing; Costs; Frequency; Induction generators; Induction motors; Manufacturing; Performance evaluation; Petroleum; Temperature; Torque;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/28.41251
Filename :
41251
Link To Document :
بازگشت