• DocumentCode
    1247075
  • Title

    Implementation of an equivalent circuit approach to the analysis of synchronous machines

  • Author

    Xiao, Y. ; Slemon, G.R. ; Iravani, M.R.

  • Author_Institution
    Dept. of Electr. and Comput. Eng., Toronto Univ., Ont., Canada
  • Volume
    9
  • Issue
    4
  • fYear
    1994
  • fDate
    12/1/1994 12:00:00 AM
  • Firstpage
    717
  • Lastpage
    723
  • Abstract
    This paper elaborates on a new approach introduced in an earlier paper for the steady-state and transient analysis of synchronous machines and demonstrates the validity and accuracy of this model for system studies. The approach is based on developing an equivalent flux linkage circuit model from the dimensions and material properties of the machine. The model provides inherent flexibility for representation of magnetic saturation, deep bar effects, and saliency. The paper includes a number of example applications in which the analytical results are compared with lest results and with those obtained from conventional analysis based on Park´s two axes machine model
  • Keywords
    equivalent circuits; machine theory; magnetic flux; synchronous machines; time-domain analysis; transient analysis; Park´s two axes machine model; accuracy; deep bar effects; equivalent circuit; equivalent flux linkage circuit model; magnetic saturation; saliency; steady-state analysis; synchronous machines; time domain; transient analysis; Equivalent circuits; Magnetic analysis; Magnetic circuits; Magnetic flux; Predictive models; Saturation magnetization; Stators; Steady-state; Synchronous machines; Transient analysis;
  • fLanguage
    English
  • Journal_Title
    Energy Conversion, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-8969
  • Type

    jour

  • DOI
    10.1109/60.368336
  • Filename
    368336