Title :
Detection of Broken Outer-Cage Bars for Double-Cage Induction Motors Under the Startup Transient
Author :
Antonino-Daviu, Jose ; Riera-Guasp, Martin ; Pons-Llinares, Joan ; Park, Jongbin ; Sang Bin Lee ; Yoo, Jiyoon ; Kral, Christian
Author_Institution :
Dept. de Ing. Electr., Univ. Politec. de Valencia (UPV), Valencia, Spain
Abstract :
Unlike single-cage rotor fault detection, fast Fourier transform (FFT)-based steady-state spectrum analysis techniques can fail to detect outer-cage faults in double-cage induction motors due to the small outer-cage current under running conditions. Double-cage motors are typically employed in applications that require loaded starts. This makes the outer cage vulnerable to fatigue failure since it must withstand the high starting current and long startup time frequently. However, there are only a few publications that investigate detection techniques specifically for double-cage motors. In this paper, considering that the influence of the faulty outer cage is strong at startup due to the large outer-cage current, detection of outer-cage faults under the startup transient is investigated. A discrete-wavelet-transform-based method is proposed as a viable solution to the detection of outer-cage faults for double-cage motors. An experimental study on fabricated copper double-cage induction motors shows that the proposed method provides sensitive and reliable detection of double-cage rotor faults compared to FFT.
Keywords :
discrete wavelet transforms; fast Fourier transforms; fault diagnosis; induction motors; spectral analysis; FFT; broken outer-cage bar detection; copper double-cage induction motors; discrete-wavelet-transform-based method; fast Fourier transform; fatigue failure; outer-cage current; outer-cage fault detection; single-cage rotor fault detection; startup transient; Bars; Discrete wavelet transforms; Induction motors; Oscillators; Rotors; Steady-state; Transient analysis; AC machine; condition monitoring; double-cage rotor; fast Fourier transform (FFT); fault diagnostics; induction motor; motor current signature analysis (MCSA); outer-cage fault; transient analysis; wavelet transform;
Journal_Title :
Industry Applications, IEEE Transactions on
DOI :
10.1109/TIA.2012.2210173