DocumentCode :
1251647
Title :
Ultrasonic imaging using a 5-MHz multilayer/single-layer hybrid array for increased signal-to-noise ratio
Author :
Emery, Charles D. ; Smith, Stephen W.
Author_Institution :
Dept. of Biomed. Eng., Duke Univ., Durham, NC, USA
Volume :
46
Issue :
5
fYear :
1999
Firstpage :
1101
Lastpage :
1119
Abstract :
Conventional diagnostic ultrasound scanners are bulky and require significant amounts of electrical power during operation. Reducing the size, weight, and consumption of electrical power is made easier through the use of highly integrated compact transmit and receive electronics that may be incorporated in the transducer handle. This necessitates the use of low voltage transmitters and low power receive preamplifiers. Conventional scanners typically use approximately 100-V pulses during transmit; therefore, decreasing the transmit voltage to 15 V decreases the transmit sensitivity. Conventional receive electronics that are located at the scanner degrade the received signal-to-noise ratio (SNR) because the array element cannot efficiently drive the coaxial cable. Transmit sensitivity and received SNR can be radically improved using a multilayer/single-layer hybrid array making integration of electronics into the transducer handle more feasible. In this paper, we discuss the design, fabrication, and testing of a 5-MHz hybrid linear array. The hybrid array included 16 multilayer transmit elements (10 /spl Omega/ impedance) and 24 single-layer receive elements at a half wavelength element pitch. Low voltage transmitters with an output resistance of 7 /spl Omega/ and high impedance JFET preamplifiers using 15 V for biasing were located adjacent to the hybrid array in the transducer handle. The transmit sensitivity and received SNR of the hybrid array were compared with a conventional array using 50-/spl Omega/ transmitters and receive preamplifiers at the scanner. The transmit sensitivity improved by 12.8 dB, and the received SNR improved by 7.8 dB, yielding an overall improvement of 20.6 dB, which compared well with predictions from the KLM model. Images of phantoms and in vivo images of the kidney obtained with the Siemens Model 1200 phased array system showed the increased SNR using the hybrid array. Estimates of penetration in tissue mimicking phantoms (/spl alpha/=- .5 dB/(cm MHz)) improved by 7 cm compared with the control.
Keywords :
antenna phased arrays; biomedical electronics; biomedical transducers; biomedical ultrasonics; kidney; linear antenna arrays; ultrasonic transducer arrays; 15 V; 5 MHz; 7 ohm; JFET preamplifiers; Siemens Model 1200 phased array system; diagnostic ultrasound scanners; in vivo images; kidney; low power receive preamplifiers; low voltage transmitters; multilayer/single-layer hybrid array; output resistance; penetration; receive electronics; signal-to-noise ratio; single-layer receive elements; transducer handle; transmit sensitivity; transmit voltage; ultrasonic imaging; Degradation; Imaging phantoms; Impedance; Low voltage; Nonhomogeneous media; Phased arrays; Preamplifiers; Transmitters; Ultrasonic imaging; Ultrasonic transducers;
fLanguage :
English
Journal_Title :
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher :
ieee
ISSN :
0885-3010
Type :
jour
DOI :
10.1109/58.796116
Filename :
796116
Link To Document :
بازگشت