DocumentCode
128030
Title
Transfer impedance measurements and simulations on perforated fully-rigid coaxial cables with the Line Injection and the Triaxial Method
Author
Kreisch, Karsten ; Kubitzek, Stephan ; Hofmeister, Christian ; Barenfanger, Jorg ; Schugt, Michael
Author_Institution
Electromagn. Compatibility, EMC Test NRW GmbH, Dortmund, Germany
fYear
2014
fDate
1-4 Sept. 2014
Firstpage
850
Lastpage
855
Abstract
The shielding concept of an electric vehicle´s drivetrain has matured over the recent past. But still, there are some issues that have to be solved. One part of the shielding concept are large multi-pole High Voltage (HV) connectors with low DC resistance. Their shape and the fact that they are built up from various components are a challenge when it comes to optimizations regarding the shielding effectiveness. The Line Injection Method (LIM) has been established by the car industry for measurement of the Transfer Impedance of these connectors. As a preparation for this kind of measurement a simple model of a HV connector is helpful. Therefore, the influence of different aperture configurations in a fully-rigid cable onto its Transfer Impedance is analyzed in this study. The measurement of the Transfer Impedance is performed with both the Line Injection and the Triaxial Method (TxM). The latter method is established for the measurement of rotationally symmetric coaxial components. Additionally, the measured values are compared to Kaden´s model of round apertures in tubular cable screens.
Keywords
coaxial cables; electric impedance measurement; electromagnetic shielding; HV connectors; Kadens model; car industry; electric vehicle drivetrain; fully-rigid coaxial cables; high voltage connectors; line injection method; low DC resistance; rotationally symmetric coaxial components; shielding concept; transfer impedance measurements; triaxial method; tubular cable screens; Apertures; Coaxial cables; Electrical resistance measurement; Electromagnetic compatibility; Frequency measurement; Impedance; Wires; Apertures; Automotive; HV connector; Line Injection Method; Screening Attenuation; Transfer Impedance; Triaxial Method;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (EMC Europe), 2014 International Symposium on
Conference_Location
Gothenburg
Type
conf
DOI
10.1109/EMCEurope.2014.6931022
Filename
6931022
Link To Document