DocumentCode :
1281197
Title :
Analytical estimation of measurement error performance of multiwavelength simultaneous monitoring circuit
Author :
Teshima, M. ; Koga, M.
Author_Institution :
NTT Opt. Network Syst. Labs., Kanagawa, Japan
Volume :
33
Issue :
19
fYear :
1997
fDate :
9/11/1997 12:00:00 AM
Firstpage :
1645
Lastpage :
1647
Abstract :
The authors estimate the frequency/power measurement error of a multiwavelength simultaneous monitoring circuit. The initial frequency measurement error is dominated by an imbalance in the bandwidths of the adjacent ports, compared with those of the optoelectrical conversion efficiency. The polarisation dependent power monitoring error is estimated to be ±0.18 and ±0.08 dB at the normalised-bandwidths of 0.4 and 0.6, respectively
Keywords :
frequency measurement; measurement errors; monitoring; optical variables measurement; power measurement; bandwidth; error; frequency measurement; multiwavelength simultaneous monitoring circuit; optoelectrical conversion efficiency; polarisation dependence; power measurement;
fLanguage :
English
Journal_Title :
Electronics Letters
Publisher :
iet
ISSN :
0013-5194
Type :
jour
DOI :
10.1049/el:19971091
Filename :
629611
Link To Document :
بازگشت