DocumentCode
128184
Title
Analysis of two different transmission-line holder systems for shielding effectiveness measurements of conductive material samples part I: Capacitive coupled TLH
Author
Kuhn, Michael ; John, Wolfgang ; Weigel, Robert
Author_Institution
EMC Dept., AUDI AG, Ingolstadt, Germany
fYear
2014
fDate
1-4 Sept. 2014
Firstpage
1311
Lastpage
1316
Abstract
This contribution deals with the analysis of the Transmission-Line Holder measurement system for determination of shielding effectiveness for material samples. Two different material sample configurations will be analysed, material sample with conductive and non conductive surface. In this part, the TLH with capacitive coupling will be analysed. This TLH is based on ASTM D4935-10 Standard. The analysis will be based on electrical circuit diagrams, calculation of transfer functions and Z-Parameters with analytical determined electrical parameters. Finally, a comparison of the analytical solution with a shielding effectiveness measurement will be done.
Keywords
electromagnetic shielding; standards; transfer functions; transmission lines; ASTM D4935-10 standard; Z-parameters; capacitive coupled TLH; capacitive coupling; conductive material samples; electrical circuit diagrams; shielding effectiveness measurements; transfer functions; transmission line holder systems; Calibration; Conductors; Equations; Materials; Mathematical model; Surface impedance; Transfer functions; ASTM D4935-10; Shielding Effectiveness; Transmission-Line Holder;
fLanguage
English
Publisher
ieee
Conference_Titel
Electromagnetic Compatibility (EMC Europe), 2014 International Symposium on
Conference_Location
Gothenburg
Type
conf
DOI
10.1109/EMCEurope.2014.6931106
Filename
6931106
Link To Document