DocumentCode :
1289713
Title :
Cold tests of quasi-optical gyrotron resonators
Author :
Fischer, R.P. ; Hargreaves, T.A. ; Fliflet, A.W.
Author_Institution :
US Naval Res. Lab., Washington, DC, USA
Volume :
39
Issue :
6
fYear :
1991
fDate :
6/1/1991 12:00:00 AM
Firstpage :
1010
Lastpage :
1012
Abstract :
Cold tests which have been performed on quasi-optical gyrotron resonators at frequencies near 94 and 120 GHz to measure cavity Q are discussed. The separation between the resonator mirrors was varied between 0.15 and 0.35 m. Quality factors ranging from 10000 to 100000 are shown. Good agreement is shown between the measured data and values calculated from scalar diffraction theory. The experimental effect of misaligning the mirrors is examined
Keywords :
Q-factor; cavity resonators; gyrotrons; 0.15 to 0.35 m; 120 GHz; 94 GHz; EHF; MW-wave type; cavity Q; mirror misalignment; quasi-optical gyrotron resonators; resonator mirrors; Dielectric loss measurement; Diffraction; Frequency measurement; Gyrotrons; Mirrors; Performance evaluation; Permittivity measurement; Q factor; Q measurement; Testing;
fLanguage :
English
Journal_Title :
Microwave Theory and Techniques, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9480
Type :
jour
DOI :
10.1109/22.81671
Filename :
81671
Link To Document :