• DocumentCode
    1294985
  • Title

    Measurement method for the large-signal admittance of mounted IMPATT diodes

  • Author

    Mansour, Nagi A. ; Goud, Paul A.

  • Author_Institution
    Dept. of Electrical Engng., Univ. of Alberta, Edmonton, Alta., Canada
  • Issue
    1
  • fYear
    1981
  • fDate
    3/1/1981 12:00:00 AM
  • Firstpage
    25
  • Lastpage
    30
  • Abstract
    The procedure employs a network analyzer and a computer optimization routine. An error network is introduced to account for drift of the measurement system and a second network is used to account for the mounted-diode parasitics. The measurement method is rapid and accurate, and is especially suitable when measurements are required at several frequencies. Typical large-signal admittance results, obtained for a Si IMPATT diode at several frequencies, are presented.
  • Keywords
    IMPATT diodes; computerised instrumentation; electric admittance measurement; network analysers; IMPATT diodes; computer optimization routine; error network; impedance measurement; large-signal admittance; network analyzer; Admittance; Frequency measurement; Impedance; Measurement uncertainty; Radio frequency; Transmission line measurements; Voltage measurement;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1981.6312433
  • Filename
    6312433