• DocumentCode
    1295191
  • Title

    An active frequency meter

  • Author

    Rehman, Mahfoozur ; Ahmed, Muslim T.

  • Author_Institution
    Dept. of Electrical Engng., Aligarh Muslim Univ., Aligarh, India
  • Issue
    2
  • fYear
    1981
  • fDate
    6/1/1981 12:00:00 AM
  • Firstpage
    160
  • Lastpage
    162
  • Abstract
    Deals with the theory and fabrication of a new frequency meter, which is used for the measurement of frequency in the range from a few hertz to 100 kHz. It is a frequency-selective bridge and is made of discrete passive R and C components and an integrated operational amplifier. At bridge balance, the frequency under measurement is given in terms of the values of resistors and capacitors only. Advantages, limitations, and sources of errors of the frequency meter are discussed. The theory is experimentally verified.
  • Keywords
    frequency meters; 100 kHz; active frequency meter; frequency-selective bridge; integrated operational amplifier; Bandwidth; Bridge circuits; Bridges; Capacitance; Capacitors; Frequency measurement; Resistors;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.1981.6312468
  • Filename
    6312468