DocumentCode :
1306008
Title :
Accuracy of Carotid Strain Estimates From Ultrasonic Wall Tracking: A Study Based on Multiphysics Simulations and In Vivo Data
Author :
Swillens, Abigail ; De Santis, Gianluca ; Degroote, Joris ; Lovstakken, Lasse ; Vierendeels, Jan ; Segers, Patrick
Author_Institution :
Inst. of Biomed. Technol., Ghent Univ., Ghent, Belgium
Volume :
31
Issue :
1
fYear :
2012
Firstpage :
131
Lastpage :
139
Abstract :
We used a multiphysics model to assess the accuracy of carotid strain estimates derived from a 1-D ultrasonic wall tracking algorithm. The presented tool integrates fluid-structure interaction (FSI) simulations with an ultrasound simulator (Field II), which allows comparison of the ultrasound (US) images with a ground truth. Field II represents tissue as random points on which US waves reflect and whose position can be updated based on the flow field and vessel wall deformation from FSI. We simulated the RF-signal of a patient-specific carotid bifurcation, including the blood pool as well as the vessel wall and surrounding tissue. Distension estimates were obtained from a wall tracking algorithm using tracking points at various depths within the wall, and further processed to assess radial and circumferential strain. The simulated data demonstrated that circumferential strain can be estimated with reasonable accuracy (especially for the common carotid artery and at the lumen-intima and media-adventitia interface), but the technique does not allow to reliably assess intra-arterial radial strain. These findings were supported by in vivo data of 10 healthy adults, showing similar circumferential and radial strain profiles throughout the arterial wall. We concluded that these deviations are present due to the complex 3-D vessel wall deformation, the presence of specular reflections and, to a lesser extent, the spatially varying beam profile, with the error depending on the phase in the cardiac cycle and the scanning location.
Keywords :
bifurcation; biomechanics; biomedical ultrasonics; blood vessels; cardiology; deformation; 1D ultrasonic wall tracking algorithm; 3D vessel wall deformation; RF-signal; arterial wall; biological tissue; blood pool; cardiac cycle; carotid artery; carotid strain; circumferential strain; flow field; fluid-structure interaction simulation; in-vivo data; intraarterial radial strain; lumen-intima interface; media-adventitia interface; multiphysics model; multiphysics simulation; patient-specific carotid bifurcation; random points; scanning location; ultrasound images; ultrasound simulator; vessel wall deformation; Acoustics; Carotid arteries; Couplings; Phantoms; Strain; Ultrasonic imaging; Carotid artery; fluid-structure interaction; strain estimation; ultrasound; wall tracking; Adult; Algorithms; Biomechanics; Carotid Arteries; Computer Simulation; Female; Humans; Image Processing, Computer-Assisted; Middle Aged; Phantoms, Imaging; Ultrasonography;
fLanguage :
English
Journal_Title :
Medical Imaging, IEEE Transactions on
Publisher :
ieee
ISSN :
0278-0062
Type :
jour
DOI :
10.1109/TMI.2011.2165959
Filename :
5997313
Link To Document :
بازگشت