Title :
Gas Hold-Up Profiles Measurement Using Ultrasonic Sensor
Author :
Rahiman, Mohd Hafiz Fazalul ; Rahim, R.A. ; Rahim, H.A.
Author_Institution :
Sch. of Mechatron. Eng., Univ. Malaysia Perlis (UniMAP), Arau, Malaysia
Abstract :
In this letter, we present a work carried out to measure gas hold-up profiles in a liquid column using a pair of ultrasonic sensors. The gas hold-up profiles from 1.85 to 7.7 mm in diameter are of interest in this investigation. The measurement setup consists of a pair of ultrasonic sensors, an experimental column, a signal conditioning circuit, and a digital storage oscilloscope. The experiment was conducted using several gas hold-up profiles, and the relationship between the ultrasonic signal and the profile were deduced. This letter explains how one could use an ultrasonic sensor to estimate gas hold-up profiles.
Keywords :
ultrasonic measurement; digital storage oscilloscope; gas hold up profile measurement; signal conditioning circuit; size 1.85 mm to 7.7 mm; ultrasonic sensor; Acoustics; Attenuation; Equations; Mathematical model; Receivers; Scattering; Ultrasonic variables measurement; Gas hold-ups; ultrasonic measurement; ultrasonic sensor;
Journal_Title :
Sensors Journal, IEEE
DOI :
10.1109/JSEN.2010.2060324