DocumentCode :
1331236
Title :
The electric strength of air. — VII
Author :
Whitehead, J.B. ; Brown, W.S.
Volume :
36
Issue :
2
fYear :
1917
Firstpage :
159
Lastpage :
188
Abstract :
In view of the variation among the values obtained by different observers, this paper aims to make a careful determination of corona-forming voltages for alternating and for positive and negative continuous voltages in the same apparatus and under the same conditions. Within the range of wire diameters used, corona appears at a lower value when the wire is positive than when it is negative, although the two curves converge for increasing diameters. The maximum excess of negative over positive, as observed, was 6.3 per cent. The values with alternating voltage coincide with those of negative continuous voltage. Positive continuous voltage therefore forms corona at the lowest value. The observations on the negative corona give values higher than any heretofore obtained. Other experiments are described, giving qualitative indications of the correctness of Townsend´s theory of ionization by collision.
Keywords :
Corona; Electric potential; Electron tubes; Generators; Voltage measurement; Windings; Wires;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Proceedings of the
Publisher :
ieee
ISSN :
0097-2444
Type :
jour
DOI :
10.1109/PAIEE.1917.6594339
Filename :
6594339
Link To Document :
بازگشت